- 92 -
FUNCTION #
DESCRIPTION
16
FEED SENSOR
Provides a sensor input for feed sensor type indexes.
17
CLEAR END OF INDEX OUTPUT
Clears the END OF HOME output. If not assigned, the END OF INDEX
will automatically clear when the next motion occurs.
18
CLEAR END OF HOME
Clears the END OF HOME output. If not assigned, the END OF HOME
will automatically clear when the next motion occurs.
19
CLEAR END OF INDEX COUNT OUTPUT
Clears the END OF INDEX output. If not assigned, the END OF INDEX
COUNT will clear when the next motion occurs.
20
CLEAR SENSOR LIMIT DISTANCE HIT
Clears the SENSOR LIMIT HIT output. The sensor limit distance is
programmed by PCX or serial commands.
21
CLEAR FAULT
Duplicates the function of the reset switch on the front of the digital drive.
It will clear non-fatal drive faults.
22
ZERO POSITION
Sets the current position of the motor to zero. All absolute positions will
be referenced to this set zero position.
23
ZERO DISPLAY
This zeroes all position query commands (FP and CP), they become zero
and are referenced to this point. Absolute position is unaffected.
24
REMEMBER POSITION
Stores the current position of an absolute index.
25
RETURN TO POSITION
Returns to the position defined by REMEMBER POSITION.