- 68 -
Once a decision is reached, the value for steps for revolution, decimal point and units can be
entered. Low resolutions, less than 1,000, are discouraged as dither is increased. For example, if
200 was selected, 360
°
/200 = 1.8
°
of dither. This could be objectionable.
Acell/Decell Shape
This option also allows the user to choose either linear ramps or mod-sine ramps for acceleration
or deceleration. The difference is shown below.
Figure 57
Mod-Sine Ramps/Linear Ramps
Torque Output
The torque output controls the amount of available torque. 200% is the drives peak rating.
100% would be the amplifiers continuous rating. Peak torque is only available for short periods.
Consult the MFR. Specs for the amplifier in use.
LIMITS
The Limits screen allows the user to set the maximum and minimum operating parameters.
Figure 58
Limits