- 163 -
Figure 65
Conveyor Application W/PCM-5
Conveyor 1 and conveyor 2 must run at the same surface velocity. Conveyor 1 is driven with a
simple variable speed drive.
Solution:
Mount the SCS-2 sync encoder on conveyor 1 and use the drive with the PCM-5
for conveyor 2.