- 137 -
NUMBER OF DIGITS NOT DISPLAYED
Sometimes the least significant digits on the numeric display are insignificant. This option
provides a way to drop digits (right to left) before they are displayed.
SIGN FLAG
If the sign flag is off, positive values will be displayed without a "+" sign. Negative values are
always displayed with the "-" sign.
SCALER MULTIPLIER, DIVISOR, AND SUBTRACTOR
These items are provided to scale the normal positioning drive values before they are displayed.
This option can be used to make the display show meaningful information (command position or
command velocity).
DISPLAY = (Value – Subtractor) * Multiplier
Divisor
These items may be any value from –32768 to 32767. A value of 0 disables any item without
error.
REFRESH DISPLAY RATE
This option determines the approximate interval at which the numeric display updates. The
actual rate may change depending on what else the positioning drive is doing. The default value
of 25 represents a .1 second rate (50 would be .2 seconds, etc.).