IOX SET UP/QUERY HARDWARE INPUT/OUTPUT
This command allows direct access to system I/O functions. All information is in hexadecimal.
X
QUERY
SET UP
0
Debounced user inputs
User inputs*
1
Actual user input status
Actual user outputs*
2
24-bit I/O port (low 8 bits)
24-bit I/O port (low 8 bits)***
3
24-bit I/O port (mid 8 bits)
24 bit I/O port (mid 8 bits)***
4
24-bit I/O port (high 8 bits)
24 bit I/O port (high 8 bits)***
5
Dip switch status (16 bits)
6
Resolver (16 bit)
7
External encoder (16 bits)
*
Any outputs set should be unassigned from any output function.
**
User I/O must be killed (KI=1), used for factory testing only.
*** Parallel port must be killed (KI1-1), used for testing only.
KI
SET UP/QUERY
KILL INPUT/OUTPUT
This command kills (inhibits) access to user I/O from the system to do direct user I/O. This is
normally only done for testing.
(Outputs should be set to zero before re-enabling.)