- 13 -
OPTIONAL FAIL-SAFE BRAKE: (Activated by the Positioning Drive)
Table III
Fail Safe Brake
Model
Holding Torque
IN-LBS
DX-308
12
DX-318
25
DX-430
45
DX-450
75
DX-480
120
DX-780
120
DX-7120
180
DX-6120
400
DX-6200
400
DX-6300
400
*DX-8200
300
*DX-8300
450
*DX-8400
600
*Special (consult factory)
COMMAND PULSE:
5-15 vdc
MODE INPUTS:
25-70 milliamps
ANALOG INPUTS:
-10 vdc to +10 vdc operating range
-12 vdc to +12 vdc absolute maximum
Different input greater than 9K ohms
SERIAL INTERFACE:
RS423 signal compatible
Xmit, Rec, and GND
INPUTS AND OUTPUTS:
Outputs:
sink or source (2 terminals);
200 Ma max (external current limit required) each
Inputs:
10 to 30 vdc (internal current limit provided)
10, 12, 15 and 24 vdc typical
Table IV
User Memory Capacity
User Memory Capacity
Drive
Drive
w/IOM-1
Drive
w/PCM-1
Drive
w/PCM-5
Jog
2
2
2
2
Home
1
1
1
1
Indexes
32
32
256
256
Programs
0
0
64
64