![Emerson EMC DX-202 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/emerson-emc/dx-202/dx-202_manual_2400893013.webp)
- 12 -
POSITIONING DRIVE SPECIFICATIONS
Specific/- 10%
Table II
Positioning Drive Specifications
DRIVE PERFORMANCE
Drive Model
#
Motor
Model #
Torque
Cont/Peak
IN/LBS
Rotor Interia
IN/LBS/SEC
Max. RPM
Bus Fuse
Shunt Fuse
KT
IN-LBS/AMP
KE
Volts/KRPM
Amplifier
Current
Ratings
DX-202
DXM-202
2/4
.0000855
3000
7 AMP
2A(S.B.)
1.8
23
1.1/2.2
DX-205
DXM-205
5/10
.000253
3000
7 AMP
2A(S.B.)
1.8
23
3.0/6.0
DX-308
DXM-308
8/16
.0005
3000
7 AMP
2A(S.B.)
2.9
34
2.8/5.6
DX-318
DXM-318
18/36
.001
3000
10 AMP
5A(S.B.)
3.38
40
5.4/10.8
DX-430
DXM-430
30/60
.0026
3000
15 AMP
5A(S.B.)
3.38
40
8.9/17.8
DX-450
DXM-450
50/85
.0052
3000
25 AMP
5A(S.B.)
3.38
40
14.8/24.0
DX-480
DXM-480
80/160
.00772
3000
30 AMP
8A(S.B.)
3.36
42
24/48
DX-780
DXM-780
80/160
.013
3000
30 AMP
8A(S.B.)
3.38
40
24/48
DX-7120
DXM-7120
120/240
.021
2000
30 AMP
8A(S.B.)
5.57
66
24/48
DX-6120
DXM-6120
120/240
.0096
3000
15 AMP
7A
8
100
15/30
DX-6200
DXM-6200
200/400
.0192
3000
20 AMP
7A
8
100
25/50
DX-6300
DXM-6300
300/600
.0268
3000
30 AMP
10A
8
100
38/76
DX-8200
DXM-8200
200/300
.04
3000
20 AMP
7A
7.4
96
27/41
DX-8300
DXM-8300
300/450
.08
3000
30 AMP
10A
7.4
96
40/60
DX-8400
DXM-8400
400/600
.12
3000
40 AMP
10A
7.4
96
54/81
INPUT VOLTAGE:
DX-202, DX-205, DX-308, DX-430, DX-450, DX-480, DX-780, DX-
7120 = 96-132 VAC, 50/60 Hz, single phase
INPUT VOLTAGE:
DX-6120, DX-6200, DX-6300, DX-8200, DX-8300, DX-8400 = 196-
264 VAC 3 PHASE 50/60 Hz
SWITCHING FREQUENCY: DX-202, DX-205, DX-308, DX-430
= 20 Khz
DX-450, DX-480, DX-780, DX-7120
= 15 Khz
DX-6120, DX-6200
= 15 Khz
DX-6300
= 12 Khz
DX-8200, DX-8300, DX-8400
= 10 Khz
DEAD BAND:
Zero
VELOCITY SIGNAL INPUT:
±
10 vdc typical (10 bit resolution speed selection
±
10 volt)
TORQUE SIGNAL INPUT:
±
vdc typical (10 bit resolution speed selection
±
10 volt)
PULSE MODE INPUT:
TTL compatible, 500 nsec minimum pulse width, 210 Khz max
frequency
ANGULAR ACCURACY:
Cable Length
15FT
50FT
100FT
Minutes
±
20
±
30
±
40
USER UNITS/REV:
Programmable Range (200-25000)
AMPLIFIER THERMAL SHUT DOWN AS DETECTED IN POWER STAGE:
All Drives:
80º - 90º C
MOTOR THERMAL SHUT DOWN AS DETECTED IN MOTOR (CASE TEMP):
All Motors:
100º - 115º C
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com