- 212 -
4 – HARDWARE CW TRAVEL LIMIT
5 – HARDWARE CCW TRAVEL LIMIT
6 – SOFTWARE CW TRAVEL LIMIT
7 – SOFTWARE CCW TRAVEL LIMIT
8 – EXTERNAL DISTANCE FAULT
FVX
QS
FEED SENSOR VELOCITY (RPM) (SIGNED)
(ONLY FOR SENSOR TYPE INDEXES)
HA
QS
HOME CYCLE ACCEL RAMP (MS TO MAX RPM)
HD
QS
HOME CYCLE DECEL RAMP (MS TO MAX RPM)
HF
QS
HOLD FUNCTION FOR INDEX (0/1)
“HF=1” = HOLD.”HF =
∅
= HOLD OFF
HG
QS
INDEX TIME BASE (HEX)
HI
QS
FEED ON HOME SENSOR VELOCITY
HL
QS
POWER UP HOME LOCK ON(1)/OFF(0)
HM
E
EXECUTE HOME CYCLE
HO
QS
FEED OFF HOME SENSOR VELOCITY
HP
QS
ABSOLUTE POSITION AFTER HOME
HR
QS
MARKER VELOCITY (ALSO HV)
HT
QS
HOME TYPE
0 – HOME TO MARKER
1 – HOME TO HOME SENSOR
2 – HOME TO HOME SENSOR THEN MARKER
3 – HOME TO/OFF HOME SENSOR
4 – HOME TO/OFF HOME SENSOR THEN MARKER
5 – HOME TO/OFF/TO HOME SENSOR
ID
Q
DRIVE IDENTIFIER
IFX
QS
INPUT FUNCTION LINE NUMBER
WHERE X = INPUT FUNCTION NUMBER
EXAMPLE: IFO = 7 ASSIGNS INPUT FUNCTION 0 TO INPUT LINE 7
IMX
E
SET DEFAULT MEMORY PARAMETERS
IN
QS
SETS INDEX TO EXECUTE ON INIT IF NO SELECT LINES
ASSIGNED
IN
QS
NO SELECT LINE INDEX
INX
E
EXECUTE SELECTED INDEX (X)
IPX
QS
INPUT FUNCTION POLARITY (0 OR 1)
WHERE X = INPUT FUNCTION NUMBER
0 SET NORMALY OFF (DEFAULT) POLARITY
1 SETS NORMALLY ON POLARITY
EXAMPLE: IPO = 1 SETS THE POLARITY OF INPUT FUNCTION
0 TO NORMALLY ON (INPUT FUNCTION 0 WILL BE
ACTIVE WHEN
THE INPUT IS OFF)
NOTE: ASSIGNING AN INPUT OR OUTPUT FUNCTION TO LINE 0 WILL HAVE THE
EFFECT OF UNASSIGNING THE FUNCTION FROM ANY LINE.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com