- 56 -
Figure 47
Example of Sinking/Sourcing Connections
NOTE:
Any connections between the customer supplied interface (stepper controller, etc.)
and the command connector should be made through a shielded cable. The shield of
this cable should be connected to the customer interface ground (source end). If no
shield connection is available at the source end, then the shield connection on the
command connector may be used. Keep in mind that this shield connection is
connected internally to chassis ground of the drive.
To execute one of the two Pulse Modes, simply select the desired mode of operation on the mode
select dip switches and put pulses into the command connector on the amplifier.
Even though the Pulse Mode of operation is being used, the Indexing Operation Mode functions
are active. This means the user could feed pulses into the amplifier and then initiate the Indexing
Mode functions from the input terminals. The serial control mode also override the Pulse Mode
in this same manner.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com