Selection number
Selection name
0
None
1
FC Port
P 5.5.1.6 Configurable Status Word STW
Use this parameter to configure status word bits. Bits 5 and 12–15 of the STW are configurable for various Drive status signals.
Default value:
1 [Profile Default]
Parameter type:
Selection
Parameter
number:
813
Unit:
–
Data type:
enum
Access type:
Read/Write
The following are the selections for the parameter.
Selection number
Selection name
0
No function
1
Profile default
10
T13 DI status
11
T14 DI status
12
T15 DI status
13
T17 DI status
15
T18 DI status
21
Thermal warning
30
Brake fault (IGBT)
40
Out of reference range
54
Running
59
On reference
P 5.5.1.7 Configurable Control Word CTW
Use this parameter to configure control word bits. The control word has 16 bits (0–15). Bits 10 and 12–15 are configurable.
Default value:
1 [Profile Default]
Parameter type:
Selection
Parameter
number:
814
Unit:
–
Data type:
enum
Access type:
Read/Write
The following are the selections for the parameter.
150
| Danfoss A/S © 2024.03 AB413939445838en-000301 / 130R1254
Application Guide | iC2-Micro Frequency Converters