Parameter
number:
1695
Unit:
–
Data type:
uint32
Access type:
Read
P 5.1.16 Reference [Unit]
Use this parameter to view the present value of reference applied in the frequency converter resulting from the choice of configuration
in
P 5.4.2 Operation Mode
.
Default value:
0.000
Parameter type:
Range (-4999.000–4999.000)
Parameter
number:
1601
Unit:
ReferenceFeedbackUnit
Data type:
int32
Access type:
Read
P 5.1.17 Reference [%]
Use this parameter to view the total reference.
Default value:
0.0
Parameter type:
Range (-200.0–200.0)
Parameter
number:
1602
Unit:
%
Data type:
int16
Access type:
Read
P 5.1.18 External Reference
Use this parameter to view the sum of all external reference sources defined in
P 5.5.3.7 Reference 1 Source
,
P 5.5.3.8 Reference 2
Source
, and
P 5.5.3.9 Reference 3 Source
.
Default value:
0.0
Parameter type:
Range (-200.0–200.0)
Parameter
number:
1650
Unit:
%
Data type:
int16
Access type:
Read
P 5.1.19 Main Actual Value [%]
Use this parameter to view the Main Actual Value sent from the frequency converter via bus.
Default value:
0.00
Parameter type:
Range (-200.00–200.00)
Parameter
number:
1605
Unit:
%
Data type:
int16
Access type:
Read
P 5.1.26 FC Port CTW 1
Use this parameter to view the 2 byte control word (CTW) received from the bus master.
Default value:
1084
Parameter type:
Range (0–65535)
144
| Danfoss A/S © 2024.03 AB413939445838en-000301 / 130R1254
Application Guide | iC2-Micro Frequency Converters