SiME332106E
Check
Part 6 Service Diagnosis
289
FXDQ-PD, FXDQ-ND
FXMQ-AR
FXAQ-AR
(1) White
(2) Yellow
(3) Orange
(4) Blue
(6) Red
(5) —
White (1)
Red (6)
Orange (3)
φ
1
φ
3
Yellow
(2)
Blue
(4)
φ
2
φ
4
M
Measuring points
1-2
1-3
1-6
2-4
2-6
Judgment criteria
No continuity
92
Ω
46
Ω
92
Ω
46
Ω
White (1)
Red (6)
Orange (3)
1
3
Yellow
(2)
Blue
(4)
2
4
M
Measuring points
1-2
1-3
1-6
2-4
2-6
Judgment criteria
No continuity
300
150
300
150
Blue
(4)
—
(5)
Orange
(3)
(2)
Yellow
(6)
Red
(1)
White
White (1)
Red (5)
Orange (3)
1
3
Yellow
(2)
Brown
(6)
Blue
(4)
2
4
M
(1) White
(2) Yellow
(3) Orange
(4) Blue
(6) Brown
(5) Red
Measuring points
1-2
1-3
1-5
2-4
2-6
Judgment criteria
No continuity
300
150
300
150
Содержание VRV RXYMQ-A Series
Страница 1: ...Service Manual RXYMQ A Series Heat Pump 50 60 Hz SiME332106E...
Страница 283: ...SiME332106E Check Part 6 Service Diagnosis 277 PCB and Circuit Diagram U V W L3B L2B L1B P1 P2 N32...
Страница 296: ...SiME332106E 290 Part 7 Appendix 1 Wiring Diagrams 291 1 1 Outdoor Unit 291 1 2 VRV Indoor Unit 293 Part 7 Appendix...
Страница 297: ...SiME332106E Wiring Diagrams Part 7 Appendix 291 1 Wiring Diagrams 1 1 Outdoor Unit RXYMQ4AVMK C 3D133942...
Страница 298: ...Wiring Diagrams SiME332106E 292 Part 7 Appendix RXYMQ4 5 6AYFK C 3D133944A...
Страница 303: ...SiME332106E Wiring Diagrams Part 7 Appendix 297 FXMQ40 50 63 80 100ARV1 3D127112 04 59...