8-10
Chapter 8. PROGRAM SETUP
the mode changes to the END mode at segments whose ON time
and pattern item time are equal.
●
●
When event type is controller status event
In this case, the event item on the programming map is skipped and
not displayed.
■
Setting up time events 1 to 5
(1) In the setting display state, move to the event 1 to 5 items of the
segment to be set up on the programming map.
(2) If you press
ENT
, the upper display starts blinking to indicate
start of entry to the No.1 setup.
(3) Press
,
,
or
to set to the No.1 setup ON time
setting.
Setting range: 0:00 to 99:59 (h:min/min:s)
0.0 to 599.9 (0.1 s)
(Select either of h:min or min:s as the time unit in setup data
C
6
4
. “:” is substituted by “.” as it cannot be displayed.)
(4) When you press
ENT
, blinking on the upper display stops. The
lower display then starts blinking to indicate start of entry to the
No.2 setup.
(When
FUNC
+
CLR
are pressed, the upper and lower displays
both return to “- - - -” and blinking stops.)
(5) Press
,
,
or
to the No.2 setup ON time set-
ting.
Setting range: ON time s 0:01 to 99:59 (h:min/min:s)
ON time s 0.1 to 599.9 (0.1 s)
(6) When you press
ENT
, blinking on the upper display stops.
(When
FUNC
+
CLR
are pressed, the upper display returns to
“- - - -” and stops blinking.)
●
●
Display
• “- - - -” is displayed for the setting values in non-set segments.
• On models that do not support time events, event 1 to 5 items on
ON time setting value
OFF time setting value
Program No. Segment No.
Pattern
tendency
LEDs corresponding to T1 to T5 lit.