7.8.1.20 “Firmware Restore” Page
The settings for restoring the controller data are shown on the “Firmware
Restore” page.
Table 84: “Firmware Restore” WBM Page
Parameters
Explanation
Source
Select the data source for the restore here.
Memory card
The data is read from the memory
card.
This selection is only enabled if a
memory card without system data is
inserted.
Network
The data is uploaded from the PC
and restored.
Packages
Select the data to be restored here.
To do this, select the corresponding entries.
All
All data is restored.
This selection only appears if the
memory card is selected as the data
source.
PLC runtime
project
The PLC runtime project is restored.
Settings
The controller settings are restored.
System
The controller operating system is
loaded. The current controller
settings are retained.
CODESYS backup file
Enter the name of the backup file for the CODESYS
project here.
The input field only appears if the network is
selected as the data source.
Settings backup file
Enter the name of the backup file for the settings
here.
The input field only appears if the network is
selected as the data source.
System backup file
Enter the name of the backup file for the system
data here.
The input field only appears if the network is