Note:
To read the specific gravity on the
hydrometer, bring the electrolyte in the
hydrometer to eye level (Fig. 5.68) and read
the graduations on the float scale
bordering on the lower meniscus.
BATTERY CHARGING
l
Constant current battery charger having the
current output of 0.9 amps must be used for
charging the 12V, 9 AH battery.
Caution:
Use only constant current battery charger.
Do not use constant voltage battery
charger.
l
If the battery charger has multiple battery
charging facility (0.25A/0.5A/0.9A), then select
the output current according to the battery
connected for charging at each bay.
Charging procedure
l
Remove the filler cover strip of battery and
connect the positive lead of the battery charger
(red colour) to the positive terminal (+) of the
battery and the negative lead of the charger
(black colour) to the negative terminal (-) of the
battery as shown in the figure. (Fig. 5.69)
Caution:
Care should be taken not to connect the
battery charger in reverse order ie. positive
lead to negative terminal and vice versa.
Incase, if the battery is connected in the
reverse order, the reverse polarity
indicator of the charger (if available in the
charger) glows and the protection fuse (if
available in the charger) blows.
Correct the connection and replace the
fuse before charging. Otherwise the
battery may not get charged.