DP120F/DP125F Troubleshooting
11-54
March 2000 © TOSHIBA TEC
Confirm the phone numbers of the
remote party.
Confirm that both parties are using
the same system password and the
both units are compatible. Then, ask
the remote party to transmit again.
Attempt the transmission again.
This may happen in some cases of
bad line condition. Attempt the trans-
mission again.
This may happen in some cases of
bad line condition. Attempt the
transmission again or ask the re-
mote party to attempt the transmis-
sion again.
This may happen in some cases of
bad line condition. Attempt the trans-
mission again.
This may happen in some cases of
bad line condition. Attempt the
transmission again.
This may happen in some cases of
bad line condition. Attempt the trans-
mission again. Or ask the remote
party to attempt the transmission
again.
This may happen in some cases of
bad line condition. Attempt the trans-
mission again.
This may happen in some cases of
bad line condition. Ask the remote
party to transmit again.
This may happen in some cases of
bad line condition. Ask the remote
party to transmit again.
Maintenance
50
53
87
B0
B1
B2
B3
B4
B5
C0
C1
Dialing and redialing was at-
tempted as many as the speci-
fied count but the line was busy.
The password did not match in a
Relay or Mailbox transmission,
and the transmission ended in fail-
ure.
There was no residual memory in
the remote party’s fax unit during
a Relay/Mailbox transmission.
DIS (GI) could not detected.
DIS/NSF that cannot be handled
by the sender is received.
The receiver received NSS/DCS
other than those declared by DIS/
NSF.
DCN is received.
DCS/DTC was not detected.
The sender performed fall-back but
the transmission was not enabled.
The receiver performed time-out
after sending FTT. Or DCN is re-
ceived.
CFR (FTT) was not detected.
Image signal carrier was not de-
tected.
High-speed signal was not de-
tected on the receiving side.
User
50
53
87
80
82
82
80
82
80
85
83
Code
Cause
Remedy
Summary of Contents for DP120F
Page 1: ...PLAINPAPERFACSIMILE File No 31200001 R0112216901 TTEC ...
Page 401: ...DP120F DP125F Circuit Description 7 92 March 2000 TOSHIBA TEC 07 05 00 Fig 7 5 1 ...
Page 656: ...DP120F DP125F Troubleshooting 11 44 March 2000 TOSHIBA TEC ...
Page 700: ...DP120F DP125F Appendix 12 2 March 2000 TOSHIBA TEC 1 2 Error Count List ...
Page 701: ...March 2000 TOSHIBA TEC 12 3 DP120F DP125F Appendix 1 3 Function List for Maintenance ...
Page 702: ...DP120F DP125F Appendix 12 4 March 2000 TOSHIBA TEC 1 4 Drum Unit ...
Page 703: ...March 2000 TOSHIBA TEC 12 5 DP120F DP125F Appendix 1 5 Memory Dump List ...
Page 706: ...SHUWA SHIBA PARK BLDG A 2 4 1 SHIBA KOEN MINATO KU TOKYO 105 8524 JAPAN ...