DP120F/DP125F Troubleshooting
11-64
March 2000 © TOSHIBA TEC
4.3.9 “DEVICE ERROR 22 to 25”
4.3.8 “DEVICE ERROR 21”
Check points
Are the terminals contacting between the
LSU and top of the Drum unit dirty or de-
formed.
Is the cable firmly connected to the Mother
PBA (CN12), between the Mother PBA
(CN24) and the Main PBA (CN12)?
When no problem is found in steps above,
the Drum unit itself, the Main PBA or the
Mother PBA may be defective.
Solutions
If dirty, clean them. If deformed, replace
the LSU.
Insert the cable to the connector firmly.
Replace in the order of: Drum unit, Main
PBA, Mother PBA.
Step
1
2
3
4.3.7 “CONFIRM DEV. UNIT”
Check points
Are the terminals contacting between the
LSU and top of the Drum unit (discharge
lamp contacts.)
Is the cable firmly connected to the Mother
PBA (CN12), between the Mother PBA
(CN24) and the Main PBA (CN12)?
When no problem is found in steps above,
the Drum unit itself or Main PBA be de-
fective.
Solutions
If dirty, clean them. If deformed, replace
the LSU.
Insert the cable to the connector firmly.
Replace in the order of: Drum unit, Main
PBA, Mother PBA.
Step
1
2
3
Check points
Is the cable from the Fuser firmly con-
nected to the LVPS (CN3), between the
Mother PBA (CN24) and the Main PBA
(CN12)?
Is the cable from the Fuser firmly con-
nected to the Mother PBA (CN4), between
the Mother PBA (CN25) and the Main PBA
(CN13)?
When no problem is found in the steps
above, the Fuser itself, the LVPS, or the
PBA's may be defective.
Solutions
Insert the cable firmly.
Insert the cable firmly.
Replace in the order of: Fuser, LVPS, Main
PBA, Mother PBA.
Step
1
2
3
Summary of Contents for DP120F
Page 1: ...PLAINPAPERFACSIMILE File No 31200001 R0112216901 TTEC ...
Page 401: ...DP120F DP125F Circuit Description 7 92 March 2000 TOSHIBA TEC 07 05 00 Fig 7 5 1 ...
Page 656: ...DP120F DP125F Troubleshooting 11 44 March 2000 TOSHIBA TEC ...
Page 700: ...DP120F DP125F Appendix 12 2 March 2000 TOSHIBA TEC 1 2 Error Count List ...
Page 701: ...March 2000 TOSHIBA TEC 12 3 DP120F DP125F Appendix 1 3 Function List for Maintenance ...
Page 702: ...DP120F DP125F Appendix 12 4 March 2000 TOSHIBA TEC 1 4 Drum Unit ...
Page 703: ...March 2000 TOSHIBA TEC 12 5 DP120F DP125F Appendix 1 5 Memory Dump List ...
Page 706: ...SHUWA SHIBA PARK BLDG A 2 4 1 SHIBA KOEN MINATO KU TOKYO 105 8524 JAPAN ...