DP120F/DP125F Removal/Replacement
3.2 Fuser Temperature Settings
When the fuser or main PBA is replaced, the fuser temperature setting procedure must be
performed.
Adjustment
Set the fuser rank (temperature rank) to the value indicated on the label adhered on the fuser as
shown in the right.
(1)
Turn the power switch ON while holding the dial keys [ 1 ] and [ 3 ] down to enter the
service mode .
(2)
Press the keys in the following order to enter the fuser temperature setting mode.
[MENU]
→
[ 9 ]
→
[ 5 ]
→
[ 0 ]
→
[ 8 ]
(3)
Select the fuser rank by pressing the [
↑
] or [
↓
] key.
(4)
Press the [ENTER] key to complete the setting and return to the standby mode.
(5)
Turn the power switch OFF to exit to the service mode.
NOTE:
Make sure not to use the moist paper for the test print.
08-03-04
Label
Fuser
Fig. 8-3-4