March 2000 © TOSHIBA TEC
11-45
DP120F/DP125F Troubleshooting
3. Initial Checks
When a problem occurs, be sure to perform the following initial checks.
3.1 Checking the Environmental Conditions for Installation
Check if the environmental conditions match the following for proper operation the machine.
•
Is the power cord plugged into an outlet satisfying the specifications? (Refer to page 2-8.)
•
Is the machine placed on a flat and level surface?
•
Is the environment for operation appropriate? (Refer to page 2-6.)
•
Is the location not subject to ammonia gas, high temperature and high humidity (near a water
supply tap, boiler, steam maker, and so on), fire, or dust?
•
Is the location not subject to direct sunlight? If it cannot be helped, attach a curtain, and so
on to shade the unit from direct sunlight.
•
Is the location well ventilated?
•
Is the location not subject to vibration?
•
Is the location not magnetized? (near a television, radio or any other electric appliances, and
so on.)
3.2 Checking the Document
Check if the document matches the following standards.
•
Does the size match the specifications? (Refer to page 2-1.)
•
Does the number of document pages to be fed automatically match the specifications? (Re-
fer to page 2-2.)
•
Are there any inappropriate paper conditions described below being used?
Fiber-reinforced paper, paper with holes, paper with wet ink or white-out, folded paper, torn
paper, paper patched together with tape, and so on.
3.3 Checking the Recording Paper
Check if the recording paper matches the following standards.
•
Does the recording paper match the specifications? (Refer to page 2-3.)
•
Has the recording paper maximum capacity of 550 (A4/Letter/Legal) sheets been exceeded?
•
Are any inappropriate paper conditions described below being used?
Wet paper, curled paper, waved paper, torn paper, used paper (with one side printed), and so
on.
Summary of Contents for DP120F
Page 1: ...PLAINPAPERFACSIMILE File No 31200001 R0112216901 TTEC ...
Page 401: ...DP120F DP125F Circuit Description 7 92 March 2000 TOSHIBA TEC 07 05 00 Fig 7 5 1 ...
Page 656: ...DP120F DP125F Troubleshooting 11 44 March 2000 TOSHIBA TEC ...
Page 700: ...DP120F DP125F Appendix 12 2 March 2000 TOSHIBA TEC 1 2 Error Count List ...
Page 701: ...March 2000 TOSHIBA TEC 12 3 DP120F DP125F Appendix 1 3 Function List for Maintenance ...
Page 702: ...DP120F DP125F Appendix 12 4 March 2000 TOSHIBA TEC 1 4 Drum Unit ...
Page 703: ...March 2000 TOSHIBA TEC 12 5 DP120F DP125F Appendix 1 5 Memory Dump List ...
Page 706: ...SHUWA SHIBA PARK BLDG A 2 4 1 SHIBA KOEN MINATO KU TOKYO 105 8524 JAPAN ...