DP120F/DP125F Function Settings
4-92
March 2000 © TOSHIBA TEC
• FUNC 21
<Remarks>
FUNC 21 Bit 7 to 4:
Minimum number of CI (Call-in) until connection with the remote party is established.
The minimum number of rings until automatic reception is initialized depends on this
setting.
FUNC 21 Bits 3 to 1:
These bits determine the CI ring volume.
Default table
US TYPE
EUR TYPE
BIT US TW SG HK DE
GB
IT
BE NL
FI
ES
AT
CH SE DK NO PT
FR
AU
7
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
6
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
5
0
0
0
0
0
1
1
1
1
1
1
0
1
1
1
1
1
1
1
4
1
1
1
1
1
0
0
0
0
0
0
1
0
0
0
0
0
1
0
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
7
6
5
4
3
2
1
0
Contents
Minimum counter of CI detection:
0001 to 1111 ... counts up for each time.
0000: 1 time
0001: 1 time
0010: 2 time
.
.
.
1111: 15 time
CI ring volume value:
000: Level 0 (minimum)
001: Level 1
010: Level 2
011: Level 3
100: Level 4
101: Level 5
110: Level 6
111: Level 7 (maximum)
Undefined
Link with User
Function Setting
—
Yes
—
Summary of Contents for DP120F
Page 1: ...PLAINPAPERFACSIMILE File No 31200001 R0112216901 TTEC ...
Page 401: ...DP120F DP125F Circuit Description 7 92 March 2000 TOSHIBA TEC 07 05 00 Fig 7 5 1 ...
Page 656: ...DP120F DP125F Troubleshooting 11 44 March 2000 TOSHIBA TEC ...
Page 700: ...DP120F DP125F Appendix 12 2 March 2000 TOSHIBA TEC 1 2 Error Count List ...
Page 701: ...March 2000 TOSHIBA TEC 12 3 DP120F DP125F Appendix 1 3 Function List for Maintenance ...
Page 702: ...DP120F DP125F Appendix 12 4 March 2000 TOSHIBA TEC 1 4 Drum Unit ...
Page 703: ...March 2000 TOSHIBA TEC 12 5 DP120F DP125F Appendix 1 5 Memory Dump List ...
Page 706: ...SHUWA SHIBA PARK BLDG A 2 4 1 SHIBA KOEN MINATO KU TOKYO 105 8524 JAPAN ...