March 2000 © TOSHIBA TEC
9-13
DP120F/DP125F Dialing and Communication Procedure
3. High-speed Transmission Procedure
The V.34 modem recommended by ITU-T (Max. transmission rate: 33.6 Kbps) is used. There-
fore, the transmission time of the image data is cut substantially when compared to conven-
tional model.
3.1 V.8/V.34 Procedure
a) Outline
• V.8 is performed as a start up procedure to switch to V.34. V.8 can connect an existing
facsimile machine to equipment using data modem or other V series modems. The V.34
modem includes a modem circuit which can also be connected to the previously recom-
mended modems. Therefore, it is downwardly compatible.
• The new techniques such as the pre-emphasis techniques *1 and the probing techniques
*2, are fully used. Pre-emphasis techniques not only make the speed of modulation method
high, but also gain the S/N ratio. Probing techniques measure the line characteristics and
optimize the modem for the line state. Therefore, these techniques do not simply speed-
ing-up transmission momentarily, but do so at the average level when the data transmis-
sion is actually performed.
• For V.8 and the pre/post-fax transmission for V.34, the procedure is speeded up by full
duplex communication.
• The following 14 types of image transmission speed are available: *3
33.6 kbps/31.2 kbps/28.8 kbps /26.4 kbps /24.0 kbps /21.6 kbps /19.2 kbps /16.8 kbps /
14.4 kbps /12.0 kbps /9.6 kbps /7.2 kbps /4.8 kbps /2.4 kbps
• The modulating speed (baud rate) can be selected from 2400, 3000, 3200 symbol/sec
(mandatory), or 2743, 2800, 3429 symbol/sec (option). The data rate can be set more
accurately than the conventional modem. *4
*1: A signal is sent by raising the output level in the high-frequency band - in which the
noise is relatively loud.
*2: The tone called “Probing Tone” is sent. The receiver measures the line characteris-
tics.
*3: In the ITU-T Recommendation, it is described as “data rate”. “Image transmission
speed” is the same as “data rate”.
*4: In the ITU-T Recommendation, it is described as “symbol speed”. “Symbol rate”, “Modu-
lating speed”, and “Baud rate” have the same meaning. This machine cannot use the
speed of “2743 symbol/sec”.
Summary of Contents for DP120F
Page 1: ...PLAINPAPERFACSIMILE File No 31200001 R0112216901 TTEC ...
Page 401: ...DP120F DP125F Circuit Description 7 92 March 2000 TOSHIBA TEC 07 05 00 Fig 7 5 1 ...
Page 656: ...DP120F DP125F Troubleshooting 11 44 March 2000 TOSHIBA TEC ...
Page 700: ...DP120F DP125F Appendix 12 2 March 2000 TOSHIBA TEC 1 2 Error Count List ...
Page 701: ...March 2000 TOSHIBA TEC 12 3 DP120F DP125F Appendix 1 3 Function List for Maintenance ...
Page 702: ...DP120F DP125F Appendix 12 4 March 2000 TOSHIBA TEC 1 4 Drum Unit ...
Page 703: ...March 2000 TOSHIBA TEC 12 5 DP120F DP125F Appendix 1 5 Memory Dump List ...
Page 706: ...SHUWA SHIBA PARK BLDG A 2 4 1 SHIBA KOEN MINATO KU TOKYO 105 8524 JAPAN ...