(10) Wipe the Laser beam window with a soft dry cloth (lens cleaner cloth). If the surfaces
require moisture to remove the dirt, use a cloth slightly dampened with water to remove
the dirt, followed by a dry cloth to remove streaks.
(11) Remove the Developer assembly from the machine. The following figure shows how to
remove the Developer assembly. Place the Developer assembly on a level surface. Cover
the assembly with a clean cloth to protect the drum from exposure to light.
CAUTION: Always hold the Developer assembly by the Green handles. Do not
touch the green drum area or the black roller. Do not leave the Drum
unit out of the machine for an extended period. Touching the drum or
exposing the Drum unit to light could lower the print quality.
Fig.10-2-9
10-2-09
Fig.10-2-10
10-2-10
Laser beam window
Developer assembly
Green handle
Green handle