DP120F/DP125F Troubleshooting
11-8
March 2000 © TOSHIBA TEC
1.2.4 LCD TEST
[MENU], [9], [2], [04]
The LCD test checks the LCD operation by turning on and off all the dots of the LCD on the
Operation panel.
(1)
Use the [
↑
] or [
↓
] key to select “04. LCD TEST”, and then press the [ENTER] key.
(2)
All the dots should turn on when the [START] key is pressed. Five seconds later, all the
dots should turn off. Visually check that all the dots are turned on and off normally. Then,
the test result input screen is displayed five seconds after the dots turn off.
(3)
Use the [
↑
] or [
↓
] key to select “1.OK” or “2.NG”, and then press the [ENTER] key.
If all dots of the LCD turn on and off normally, select “1.OK.” If even one dot fails to turn on
and off, select “2.NG.”
(4)
The "OPERATION COMPLETED" message is displayed and the unit returns to the test
item select screen of the individual test.
<Remarks>
The result of the LCD TEST can be checked with the self test report. For
printing the self test report, refer to “1.3 TEST RESULT LIST” on page 11-
14.
If the result of the LCD TEST is judged to be NG, solve the problem by
referring to “1.5.1 OPE. PANEL TEST” on page 11-16.
LCD TEST
ENTER TEST RESULT
1.OK
2.NG
Display for 5sec
→
LCD TEST
LCD WILL CHANGE BLACK
AND THEN CLEAR
PRESS START KEY
Summary of Contents for DP120F
Page 1: ...PLAINPAPERFACSIMILE File No 31200001 R0112216901 TTEC ...
Page 401: ...DP120F DP125F Circuit Description 7 92 March 2000 TOSHIBA TEC 07 05 00 Fig 7 5 1 ...
Page 656: ...DP120F DP125F Troubleshooting 11 44 March 2000 TOSHIBA TEC ...
Page 700: ...DP120F DP125F Appendix 12 2 March 2000 TOSHIBA TEC 1 2 Error Count List ...
Page 701: ...March 2000 TOSHIBA TEC 12 3 DP120F DP125F Appendix 1 3 Function List for Maintenance ...
Page 702: ...DP120F DP125F Appendix 12 4 March 2000 TOSHIBA TEC 1 4 Drum Unit ...
Page 703: ...March 2000 TOSHIBA TEC 12 5 DP120F DP125F Appendix 1 5 Memory Dump List ...
Page 706: ...SHUWA SHIBA PARK BLDG A 2 4 1 SHIBA KOEN MINATO KU TOKYO 105 8524 JAPAN ...