March 2000 © TOSHIBA TEC
10-3
DP120F/DP125F Preventive Maintenance
2.2 Periodically Replaced Parts
The following table shows the parts to be replaced periodically on this facsimile machine. Be
sure to check and clean these parts at the time of the periodical checkups and when calling on
the user.
If the maintenance contract has been made, replace the parts that have reached the end of their
lives. If the maintenance contract has not been made, recommend to replace such parts (to be
charged). As for the replacing procedure, refer to “Chapter 8: Removal/Replacement/Adjust-
ment.”
Name
Life
ADF pad assembly
12,000 sheets or 1 year
ADF drive roller
24,000 sheets or 2 years
Lower ADF roller
24,000 sheets or 2 years
Transfer unit
60,000 sheets
Fuser
60,000 sheets
Paper pickup roller
60,000 sheets
Fan motor
30,000 hours
Developer unit
60,000 sheets
Other rollers and gears
60,000 sheets