March 2000 © TOSHIBA TEC
5-9
DP120F/DP125F Mechanical Description
3.2 Components of Reception Section
The reception section consists of tray area, RX drive area, laser scanner area, print area,
Optional recording paper tray, and Optional bypass tray.
3.2.1 Tray Area
The tray area consists of the Recording paper tray, Paper empty sensor, and Paper size sen-
sor. The Paper empty sensor determines if the Recording paper tray is empty, and the Paper
size sensors detect the recording paper size.
•
Recording paper tray
Tray in which recording paper is loaded. The sizes of paper that can be set are A4, Letter
and Legal (A4, LT & LG). (Refer to Page 2-3.)
•
Paper empty sensor
Detects the presence of recording paper in the Recording paper tray. The sensor is
located in the upper part of the tray base. (Refer to Page 6-11.)
•
Paper size sensors
One of the three Paper size sensors is turned on by the Paper guide B in the Recording
paper tray and detects the size of paper loaded in the tray.
The sensors are located in the rear of the tray base. (Refer to page 6-11.)
Tray area
Print area
Laser scanner area
RX drive area
Optional recording
paper tray
Fig. 5-3-2
05-03-02
Optional bypass tray
Summary of Contents for DP120F
Page 1: ...PLAINPAPERFACSIMILE File No 31200001 R0112216901 TTEC ...
Page 401: ...DP120F DP125F Circuit Description 7 92 March 2000 TOSHIBA TEC 07 05 00 Fig 7 5 1 ...
Page 656: ...DP120F DP125F Troubleshooting 11 44 March 2000 TOSHIBA TEC ...
Page 700: ...DP120F DP125F Appendix 12 2 March 2000 TOSHIBA TEC 1 2 Error Count List ...
Page 701: ...March 2000 TOSHIBA TEC 12 3 DP120F DP125F Appendix 1 3 Function List for Maintenance ...
Page 702: ...DP120F DP125F Appendix 12 4 March 2000 TOSHIBA TEC 1 4 Drum Unit ...
Page 703: ...March 2000 TOSHIBA TEC 12 5 DP120F DP125F Appendix 1 5 Memory Dump List ...
Page 706: ...SHUWA SHIBA PARK BLDG A 2 4 1 SHIBA KOEN MINATO KU TOKYO 105 8524 JAPAN ...