vii
ABOUT THIS MANUAL
Presented here is information regarding the documents that are included with this
manual (Structure), its history of release and revisions (Revision History), how the
content is organized (Organization), and the conventions used to present the information
in this manual (Conventions Used).
S
TRUCTURE
This T100 manual, PN 068070000, is comprised of multiple documents, assembled in
PDF format, as listed below.
Part No.
Rev Name/Description
06807000
0
A
Operation Manual, T100 UV Flourescence SO2 Analyzer
05036
D
Appendix A, Menu Trees and related software documentation
06845
A
Spare Parts List (in Appendix B of this manual)
04796
E
Appendix C, Repair Form
06908
A
Interconnect Diagram (in Appendix D of this manual)
069080100
A
Interconnect Table (in Appendix D of this manual)
Schematics (in Appendix D of this manual)
04354
D
PCA, 04003, Pressure Flow Sensor Board
04524
D
PCA, 04522, Relay Card
04181
H
PCA, 04180, PMT Preamp
05064
C
PCA, 05063, Dual UV Detector
04693
E
PCA, 04692, UV Lamp Driver
04932
C
PCA, Thermo-Electric Cooler Driver
04468
B
PCA, 04467, Analog Output Isolator
05803
B
SCH, PCA 05802, MOTHERBOARD, GEN-5
06698
D
SCH, PCA 06670, INTRFC, LCD TCH SCRN,
06882
B
SCH, LVDS TRANSMITTER BOARD
06731
A
SCH, AUX-I/O BOARD
Note
We recommend that this manual be read in its entirety before any attempt is made to
operate the instrument.
O
RGANIZATION
This manual is divided among three main parts and a collection of appendices at the end.
Part I
contains introductory information that includes an overview of the analyzer,
descriptions of the available options, specifications, installation and connection
instructions, and the initial calibration and functional checks.
Part II
comprises the operating instructions, which include basic, advanced and remote
operation, calibration, diagnostics, testing, validating and verifying, and ends with
specifics of calibrating for use in EPA monitoring.
Summary of Contents for T100
Page 2: ......
Page 4: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer iv This page intentionally left blank ...
Page 6: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer vi This page intentionally left blank ...
Page 10: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer x This page intentionally left blank ...
Page 20: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer xx ...
Page 21: ...21 PART I GENERAL INFORMATION ...
Page 77: ...77 PART II OPERATING INSTRUCTIONS ...
Page 78: ...Getting Started Teledyne ML T100 UV Fluorescence SO2 Analyzer 78 ...
Page 207: ...207 PART III TECHNICAL INFORMATION ...
Page 208: ...208 06807A DCNxxxx ...
Page 210: ...210 06807A DCNxxxx This page intentinally left blank ...
Page 362: ...APPENDIX B T100 Spare Parts List T100 Instruction Manual B 2 068070000 Rev A ...