APPENDIX A - Version Specific Software Documentation
Teledyne ML - T100 UV Fluorescence SO2 Analyzer
A-10
05036 Rev D
4) SAMPLE
LED
5) CAL
LED
6) FAUL T
LED
7) AUDIBLE
BEEPER
8) ELEC TEST
9) OP TIC
TEST
10) DARK TEST
4
11) P REAMP RAN GE HI
12) ST SYSTEM OK
13) ST CON C VALID
14) ST HIGH RAN GE
15) ST ZERO CAL
16) ST SPAN CAL
17) ST DIAG MO DE
ST LOW SPAN CAL
3
18) ST LAMP ALARM
19) ST DARK CAL ALARM
20) ST FLOW ALARM
21) ST PRES S ALARM
22) SR TEMP AL ARM
23) ST HVP S ALARM
24) ST SYSTEM OK2
25) ST CONC AL ARM 1
26) ST CONC AL ARM 2
27) ST HIGH RANGE 2
28) RELAY WATCHDO G
29) RCELL HEATER
30) IZS HEATER
2
31) CAL VALVE
32) SP AN VALVE
33) P MT SIGNAL
LOW SPAN VALVE
3
34) ZERO VALVE
1
35) DARK SHUTTER
36 INTERN AL
AN ALOG
VOLTAGE
SIGN AL S
54
(se e Appendix A)
CFG
ACAL
1
CLK
PASS
RNGE
DAS
MORE
COMM
VARS
1
Only appears if valve option is installed.
2
Only relevant to analyzers with IZS options installed.
3
T100H, M100EH
4
T100, T100U, M100E, M100EU
5
T100U, M100EU
ANALOG
OUTPUT
LAMP
CALIBRATION
0) EXT ZERO CAL
1) EXT SP AN CAL
EXT LOW SPAN
3
2) MAIN T
MO DE
3) LANG2 SELECT
SIGNAL
I/O
OFF
ON
ENTR
Start step Test
SAMPLE
DIAG
PREV NEXT
NONE
PMT READING
UV READING
SAMPLE PRESSURE
SAMPLE FLOW
RCELL TEMP
CHASSIS TEMP
IZS TEMP
2
PMT TEMP
HVPS VOLTAGE
PREV NEXT
ENTR
ENTR
OPTIC
TEST
ELECTRICAL
TEST
Starts Test
Starts Test
AOUTS CALIBRATED
CONC OUT 1
CONC OUT 2
TEST OUTPUT
CAL
RANGE
REC OFFSET
AUTO CAL
CALIBRATED
0.1V 1V
5V 10V CURR
SET>
EDIT
CAL
OFF
ON
SET>
<SET
<SET
ANALOG I/O
CONFIGURATION
ENTR
Starts Test
PRESSURE
CALIBRATION
ENTR
Starts Test
ENTR
Starts Test
TEST
CHANNEL
OUTPUT
FLOW
CALIBRATION
ENTER SETUP PASS: 818
PMT
5
CALIBRATION
Figure A-8: Secondary Setup Menu (DIAG)
Summary of Contents for T100
Page 2: ......
Page 4: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer iv This page intentionally left blank ...
Page 6: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer vi This page intentionally left blank ...
Page 10: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer x This page intentionally left blank ...
Page 20: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer xx ...
Page 21: ...21 PART I GENERAL INFORMATION ...
Page 77: ...77 PART II OPERATING INSTRUCTIONS ...
Page 78: ...Getting Started Teledyne ML T100 UV Fluorescence SO2 Analyzer 78 ...
Page 207: ...207 PART III TECHNICAL INFORMATION ...
Page 208: ...208 06807A DCNxxxx ...
Page 210: ...210 06807A DCNxxxx This page intentinally left blank ...
Page 362: ...APPENDIX B T100 Spare Parts List T100 Instruction Manual B 2 068070000 Rev A ...
Page 370: ...APPENDIX D ELECTRONIC SCHEMATICS T100 Instruction Manual D 2 068070000 Rev A ...