Teledyne ML - T100 UV Fluorescence SO2 Analyzer
Introduction, Features and Options
25
OPTION
OPTION
NUMBER
DESCRIPTION/NOTES
REFERENCE
Carrying Strap/Handle
Side-mounted strap for hand-carrying analyzer
29
Extends from “flat” position to accommodate hand for carrying.
Recesses to 9mm (3/8”) dimension for storage.
Can be used with rack mount brackets, Option 21.
Cannot be used with rack mount slides.
N/A
CAUTION
GENERAL SAFETY HAZARD
A fully loaded T100 with valve options weighs about 18 kg (40
pounds).
To avoid personal injury we recommend that two persons lift and
carry the analyzer.
Disconnect all cables and tubing from the analyzer before
carrying it.
Analog Inputs
Used for connecting external voltage signals from other instrumentation (such as
meteorological instruments).
64
Also can be used for logging these signals in the analyzer’s internal
DAS
Current Loop Analog
Outputs
Adds isolated, voltage-to-
current conversion circuitry to the analyzer’s analog
outputs.
41
Can be configured for any output range between 0 and 20 mA.
May be ordered separately for any of the analog outputs.
Can be installed at the factory or retrofitted in the field.
Sections 3.4.4,
4.6.1, 4.8.4, and
4.8.4.5
Parts Kits
Spare parts and expendables
42A
Expendables Kit
includes a recommended set of expendables for
one year of operation of this instrument including replacement sample
particulate filters.
Appendix B
43
Expendables Kit with IZS
includes the items needed to refurbish the
internal zero air scrubber (IZS) that is included.
Appendix B
45
Spare Parts Kit
includes spares parts for one unit.
Appendix B
NO Optical Filter
Recommended for high NOX backgrounds.
47
Required for EN Certification.
N/A
Calibration Valves
Used to control the flow of calibration gases generated from external sources, rather
than manually switching the rear panel pneumatic connections.
50A
Two Teflon® solenoid valve sets located inside the analyzer:
Zero/Span
valve switches between zero air and span gas;
Sample/Cal
valve switches between sample gas and calibration gas.
Sections 3.5.3,
3.5.4, 6.4, 6.5 and
6.6
Internal Zero/Span (IZS) Gas
Generator
Generates internal zero air and span gas.
51A
Includes heated enclosure for a permeation tube (tube not included
–
see SO
2
IZS Permeation Tubes options), an external scrubber for
producing zero air and a set of valves for switching between the
sample gas inlet and the output of the zero/span subsystem,
functionally very similar to the valves included in the zero/span valve
option.
Summary of Contents for T100
Page 2: ......
Page 4: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer iv This page intentionally left blank ...
Page 6: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer vi This page intentionally left blank ...
Page 10: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer x This page intentionally left blank ...
Page 20: ...Teledyne ML T100 UV Fluorescence SO2 Analyzer xx ...
Page 21: ...21 PART I GENERAL INFORMATION ...
Page 77: ...77 PART II OPERATING INSTRUCTIONS ...
Page 78: ...Getting Started Teledyne ML T100 UV Fluorescence SO2 Analyzer 78 ...
Page 207: ...207 PART III TECHNICAL INFORMATION ...
Page 208: ...208 06807A DCNxxxx ...
Page 210: ...210 06807A DCNxxxx This page intentinally left blank ...
Page 362: ...APPENDIX B T100 Spare Parts List T100 Instruction Manual B 2 068070000 Rev A ...
Page 370: ...APPENDIX D ELECTRONIC SCHEMATICS T100 Instruction Manual D 2 068070000 Rev A ...