Parameterizing motor data
ID 442289.06
38
Operation manual POSIDYN® SDS 5000
5
WE
KEEP
THINGS
MOVING
The following actions will make it easier for you to enter parameters:
•
You can calibrate the parameter
B05 Commutation-offset
with the aid of the action
B40 Phase test
.
•
The parameters
B52
to
B55
can be determined using action
B41 Autotune motor
.
•
The current controller can be adapted using the action
B42 Activate current controller
.
The actions are described in section 12.5 Actions.
5.4
Further motor datas
5.4.1
Current controller
The parameters
B64
to
B68
are important for the setting of the current controller. If an initial test does not
provide the desired running result with the default setting in the parameters, current controller optimization is
recommended. It is performed with the action
B42 Optimize current controller
. Now save the measured values
with
A00 Save values
.
5.4.2
Thermal model
The parameters
B70
,
B71
and
B72
describe a motor model for the protection of the motor. The default values
are usually sufficient.
5.4.3
Absolute Limit values
The parameters
B82 I-max
and
B83 n-max motor
are limit values which may never be exceeded.
Information
Since parameters in the parameter lists and assistant are indicated or hidden based on how
B20
is set, all parameters are not always visible for each setting.