13.3.10 40:Invalid data
Triggering
Level
Response
Fault counter
A data error was detected when initializing the
non-volatile memory.
Fault
The inverter cannot be enabled.
Z40
Cause
Description
Measure
Acknowledgement
1:Error
Low level write/read error or timeout.
Replace the inverter.
Not confirmable
2:BlockMiss
unknown data block
3:DataSecurity
Block has no data security.
4:CheckSum
Block has a check sum error.
5:R/O
Block is r/o.
6:ReadErr
Start-up phase: Block read error
7:BlockMiss
Block not found
17:Error
Low level write/read error or timeout
18:BlockMiss
unknown data block
19:DataSecurity
Block has no data security.
20:CheckSum
Block has a check sum error.
21:R/O
Block is r/o.
22:ReadErr
Start-up phase: Block read error
23:BlockMiss
Block not found.