Description of the causes
07
hex
The Teleserver concluded remote maintenance.
9
08
hex
The Teleserver rejected the serial number.
10
09
hex
The Teleserver rejected the serial number.
10
0A
hex
An internal error occurred.
5
0B
hex
An internal error occurred.
5
0C
hex
The inverter is waiting for the connection to POSITool.
11
0D
hex
An internal error occurred.
5
0E
hex
An error occurred during flow monitoring between Teleserver and
inverter.
6
0F
hex
A CRC error was determined for the HTTP response from the
Teleserver.
7
10
hex
An internal error occurred.
5
11
hex
An error occurred during flow monitoring between Teleserver and
inverter.
6
12
hex
An error occurred during flow monitoring between Teleserver and
inverter.
6
13
hex
An internal error occurred.
5
14
hex
An internal error occurred.
5
15
hex
An internal error occurred.
5
Cause no.
Description
1
Establishment of the TCP/IP connection to the Teleserver failed.
Check all network settings and the firewall.
2
The inverter tried to connect with the Teleserver PC, but the specified PC actively
denied the attempted connection.
Check whether the Teleserver (LAN) was installed correctly and is running. You can
check the connection to the Teleserver with POSITool, for example.
3
The inverter cannot access the IP address of the Teleserver with the current network
settings (IP address and subnet mask).
Check the IP address of the inverter and Teleserver.
4
An attempt was made to establish a TCP/IP connection to a Teleserver which already
exists.
Exit remote maintenance correctly and start remote maintenance again.
5
An internal error was found.
Contact STÖBER ANTRIEBSTECHNIK GmbH & Co. KG, see chapter 1.4 Further