Integrated Bus
ID 442289.06
106
Operation manual POSIDYN® SDS 5000
11
WE
KEEP
THINGS
MOVING
11.4.8
Activation of remote maintenance
Before you can activate remote maintenance, the following prerequisites must be met:
1. The inverter is connected with the local network, Intranet or Internet.
2. The inverter has been given valid information so that it can communicate via the local network, Intranet
or Internet (see chapter 11.4.1 System administration).
3. In parameter
A167 remote service source
you have entered the signal with which remote maintenance
can be started (e.g., a binary signal on binary input BE1).
4. On the inverter that is the gateway to the network, you specify in parameter
A168 remote service with
session-ID
whether remote maintenance should be protected with a session ID.
5. The service employee has a PC which is connected to the local network, Intranet or Internet and version
V 5.4 or later of the POSITool software is installed on this PC.
Proceed as shown below:
The session ID provides additional security for remote maintenance. If Parameter
A168
is set on the gateway
inverter so that the session ID is requested for remote maintenance, the service technician cannot establish
a connection to the inverter without the session ID.
If the blue LED does not flash even though remote maintenance is activated, parameter
A178
indicates the
cause.
Information
As the person responsible for the machine, ensure (e.g., by telephone) that the device is accessed
for remote maintenance by an authorized person.
Do not allow a request to exist for an unnecessarily long period of time.
Activation of remote maintenance
1. The machine technician switches on the signal parameterized in
A167
for the inverter which is to have
remote service.
The inverters register. The LEDs on the front of the inverters suddenly flash once.
After the connection to the Teleserver is established, the blue LEDs on the front of the inverters begin
flashing at regular intervals. The inverters indicate their serial number on their displays.
If
A168 = 1:with SessionID
is set on the gateway inverter, the session ID is indicated in addition to the
serial number.
The person responsible for the machine has activated remote maintenance. He informs the service
technician and gives him/her the serial number of a device in the IGB network and, if applicable, the
session ID.