Diagnosis
Operation
manual
POSIDYN®
SDS
5000
15
4
ID 44
22
8
9
.0
6
WE KEEP THINGS MOVING
13
27:X4-AX5000 gef
A functional AX 5000 option was
found at X4 although the
incremental encoder or EnDat
encoder was parameterized or no
EnDat encoder is connected to
option AX 5000.
•
Check the setting of the
H00
parameter.
•
Check the connection of the encoder at the POSISwitch
AX 5000.
Programmed
acknowledgement
28:X4-EnDatfound
An EnDat encoder was detected at
X4 although a different encoder was
parameterized.
Check the setting of the
H00
parameter.
Programmed
acknowledgement
29:AX5000/IncEnc
A faulty POSISwitch AX 5000 option
at X4 or a wire break in the A-
channel for an incremental encoder
was detected.
•
Replace the AX 5000 option.
•
Check the encoder cable of the incremental encoder.
Programmed
acknowledgement
30:Opt2 incomp
Option 2 is not the latest version.
Install the latest version of the option board.
Programmed
acknowledgement
31:X140EnDatAlar
The EnDat encoder at X140 reports
an alarm.
Replace the motor.
Programmed
acknowledgement
32:X140EnDatCRC
Errors accumulate during data
transfer. The encoder is not
available.
•
Make sure that the correct encoder type is connected.
•
Check the connection and shielding of the encoder
cable.
•
Reduce the electromagnetic interference.
Programmed
acknowledgement
33:IGB Angle dif.
G297
exceeded on the IGB
•
Check the parameterization of G297.
•
Check the producer.
Programmed
acknowledgement
Cause
Description
Measure
Acknowledgeme
nt
Summary of Contents for POSIDYN SDS 5000