Diagnosis
Operation
manual
POSIDYN®
SDS
5000
16
0
ID 44
22
8
9
.0
6
WE KEEP THINGS MOVING
13
13.3.11 41:Temp.MotorTMS
Resolution
Level
Response
Fault counter
Motor temperature sensor
reports overtemperature
(connection clamp X2).
Warning and malfunction can
be parameterized in
U15.
The parameterized malfunction reaction in the
A29
parameter.
Z41
Possible cause
Test
Measure
Acknowledgement
The motor temperature
sensor is not connected.
Check whether the motor temperature
sensor is connected to X2 and whether
the wiring is OK.
Connect the cable properly.
Switch the device on/off or
programmed
acknowledgement
The motor is overloaded
Check whether the operating conditions
have caused the motor to overheat (load
state, ambient temperature of the motor,
etc.).
•
Check and, if necessary, correct the
drive design.
•
Check whether a blockage caused
overheating.
The KTY evaluation is
activated although an A-
device is not involved.
Your device indicates a HW version of 190
or lower and
B38
is set to
1: KTY 84-1xx
.
•
If the motor allows it, set
B38 = 0:
PTC
.
•
Replace the inverter with an A-device
(HW version 200 or higher).
Summary of Contents for POSIDYN SDS 5000