Integrated Bus
ID 442289.06
96
Operation manual POSIDYN® SDS 5000
11
WE
KEEP
THINGS
MOVING
When you use the setting
Only DHCP
, you wait for a reply on the DHCP server without a timeout.
If the inverter does not receive an IP address from the DHCP server even though one is present, the address
can be enabled by the network administrator. It is possible that the configuration of the DHCP server will also
have to be expanded. SDS 5000 inverters can be unambiguously recognized by the DHCP server with the
MAC address 00:11:39:xx:xx:xx.
If the network does not have a DHCP server, remove the checkmark from the checkbox and manually enter
an IP address and a subnet mask in the fields:
Fig. 11-11: Manual setting of the IP address for X3 A
If the inverter is located in the same network as the PC on which you are making the settings in POSITool,
you can use the IP address and the subnet mask from the
Determine settings from network adapter
button.
When you click the button, the following dialog screen appears:
Fig. 11-12: The
Select network adapter
dialog screen