Direct connection
A direct connection means the direct connection of a PC with POSITool to an SDS 5000 or an IGB network
via a cable without any other network components for commissioning, diagnostic or maintenance
purposes.You can establish a direct connection with an SDS 5000 or an IGB network.
11.2.1
Requirements for a direct connection
Note the following rule for the direct connection:
•
The socket of the gateway device and the computer's network connection must have IP addresses on the
same subnet.
Information
To coordinate the IP addresses of the gateway device and the computer, you have the option of
changing the IP address of either the computer or the gateway device. However, since you
generally need administrator rights to change the IP address of the computer, we recommend
changing the IP address of the gateway device.
Information
Please note that the device has two RJ45 sockets (X3A and X3B). Since one socket must be
access concretely for a direct connection, the related parameters are created as array parameters.
Element 0 contains the settings for socket X3A and element 1 for socket X3B. Make the settings
described in this section appropriately for the socket with which you will connect the gateway
device with the computer.