Parameterizing brake data
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
51
7
7.4
B20 = 2:Vector control
Proceed as follows for parameterization:
You can make these settings with the
General settings
assistant on the
Holding brake
page:
Fig. 7-3
: General settings
assistant,
Holding brake
page
Parameterize the brake control for
B20
=
2:vector control
1. Activate the brake control in parameter
F08
.
2. Specify which brakes are connected to the brake module in
F09
.
3. Enter the time for which the motor should remain magnetized after triggering the braking procedure in
B27
.
4. In
B25
, enter the percentage of halt flux that should remain after the time in
B27
.
5. Enter the time that the brake requires to be set in
F07
. If you use two brakes at the brake module, enter
the one with the longer set time.
6. Enter the time that the brake requires to be released in
F06
. If you use two brakes at the brake module,
enter the one with the longer release time.
7. Transfer the parameters to the inverter and save them in it.
8. Switch the inverter off and back on again.
You have now parameterized the brake control.
Summary of Contents for POSIDYN SDS 5000