![Stober POSIDYN SDS 5000 Operation Manual Download Page 155](http://html.mh-extra.com/html/stober/posidyn-sds-5000/posidyn-sds-5000_operation-manual_1381280155.webp)
Diagnosis
O
peration
man
ual
POSIDYN
®
SDS
5000
15
5
ID 442
289
.06
WE KEEP THINGS MOVING
13
34:battery low
When switching on the inverter, it
was determined that the voltage of
the battery has fallen below the
warning limit of the encoder.
Referencing of the axis remains
intact. However, the remaining
service life of the backup battery is
limited.
•
Replace the AES battery before the next time the inverter
is switched off. Note also the Absolute Encoder Support
AES operating instructions (see section 1.3 Further
Programmed
acknowledgement
35:battery empty
When switching on the inverter, it
was determined that the voltage of
the battery has fallen below the
minimal voltage of the encoder.
Referencing of the axis has been
deleted. The backup battery is no
longer able to retain the position in
the encoder over the time during
which the inverter in switched off.
•
Referencing the axis.
•
Replace the AES battery before the next time the inverter
is switched off. Note also the Absolute Encoder Support
AES operating instructions (see section 1.3 Further
Programmed
acknowledgement
Cause
Description
Measure
Acknowledgeme
nt
Summary of Contents for POSIDYN SDS 5000
Page 194: ...Notes WE KEEP THINGS MOVING ...