Integrated Bus
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
109
11
Comply with the following points concerning activated remote maintenance:
•
There must be at least one inverter in the IGB network which is enabled for remote maintenance so that
the Internet connection can be maintained. When an active Internet connection exists, you can enable or
disable inverters in the IGB network at all times.
This is done with the signal specified in
A167 remote service source
.
•
If you are downloading a new configuration via remote maintenance, set the parameters which are
relevant to remote maintenance the same as for the configuration up to now so that you avoid a premature
termination of the connection due to errors in the parameterization. This refers primarily to the parameter
A167 remote service source
in which the signal which will start remote maintenance is specified..
•
If you are performing a live firmware update via remote maintenance and then start the firmware again
immediately afterwards, a new start is performed on the inverters. In this case, the remote maintenance
connection is disconnected.
The entire IGB network is shown in POSITool. The inverters which are not enabled for remote
maintenance are marked with a red "stop sign." You can use the buttons at the bottom for the inverters
which are enabled for remote maintenance to
- read data from the inverters
- trigger the sending of data to the inverters
- execute a live firmware update.