![Stober POSIDYN SDS 5000 Operation Manual Download Page 138](http://html.mh-extra.com/html/stober/posidyn-sds-5000/posidyn-sds-5000_operation-manual_1381280138.webp)
Service
ID 442289.06
138
Operation manual POSIDYN® SDS 5000
12
WE
KEEP
THINGS
MOVING
12.5.2.4
B42 Optimize current controller
NOTICE
During the action, the motor turns at approx. 2000 Rpm.
For this reason ensure the motor and the mechanism coupled to it are allowed to be operated at this speed
and can rotate freely!
During the action, you hear clicking noises at regular intervals. The action takes approx. 20 minutes.
NOTICE
Danger due to delayed shut-down.
If you have enable the action via local operation, the action can only be interrupted with a very long delay
by deactivating the enable!
When you start the action, the parameters of the current controller are specified again (
B64
to
B68
).
During activation, the enable must be inactive. If you have started the action in
B42.0
, you must activate the
enable. After the action was concluded, you must deactivate the enable again. You can then read the
measured values in
B64
to
B68
.
If a quick stop request occurs during the action, the drive is halted immediately.
For the duration of the action, the cycle time is set internally to 32 msec.
You can read the following results from the third element (
B42.2
):
0: error free:
The action was executed without errors and concluded.
1: aborted:
The action was aborted by turning off the enable.
Summary of Contents for POSIDYN SDS 5000