Integrated Bus
ID 442289.06
82
Operation manual POSIDYN® SDS 5000
11
WE
KEEP
THINGS
MOVING
Parameter
A155
indicates the current state of the IGB-Motionbus:
The following conditions apply to a change in state:
State
Description
0: IGB Booting
The IGB is booting. The connected inverters register
on the IGB network and synchronize themselves. In
this condition, values for parameters
A120
and
A121
will be sampled and applied for further operation
without change.
1: Single
No IGB network with other inverters is currently
established. The functions
remote maintenance
or
direct connection
can be used.
2: IGB running
Several inverters have established an IGB network.
The functions
remote maintenance
or
direct
connection
(with POSITool) can be used. The
IGB-
Motionbus
function is not being used or cannot be
used for one of the following reasons,
•
The function was not selected during configuration
•
The parameter
A120 IGB Address
was not
unambiguously set for all stations
•
A121 IGB nominal number
was not
parameterized.
•
Because after changing of
A120
or
A121
the
values were not saved and the device was
switched off and on again, or because no other
device has triggered a bus reset.
3: IGB-Motionbus
The inverters in the IGB network are sending and
receiving cyclic data. In this state, the addition of
further inverters has no effect on the existing IGB-
Motionbus.
4: Motionbus Error
The state
A155 = 3:IGB-Motionbus
was already
achieved once and was exited due to an error.
State
Condition
1: Switch on
Power was turned on
2: Nobody found
Either this SDS 5000 found no other inverter with
which it could establish an IGB network or an already
existing connection to other inverters via IGB was
disconnected.
3: Partner found
At least one directly connected SDS 5000 was found.
All partners that were found have organized and
synchronized themselves on the IGB.
Summary of Contents for POSIDYN SDS 5000