Diagnosis
O
peration
man
ual
POSIDYN
®
SDS
5000
18
5
ID 442
289
.06
WE KEEP THINGS MOVING
13
13.3.36 #00c:StackOverfl
13.3.37 *ParaModul ERROR:update firmware!
Triggering
Level
Response
A stack that is too small was detected.
Fault
The motor coasts, the microprocessor is stopped and all device
functions are inoperable.
Possible cause
Test
Measure
Acknowledgement
Error in code memory (bit
dumped, permanent).
Reestablish the operating conditions at
the time of the error and check whether
the error occurs again.
•
Reload the application in the
inverter and save it.
•
Perform a firmware upgrade.
Switch device off/on
EMC error
Check the wiring for EMC-compliant
design.
Wire according to EMC regulations.
Resolution
Level
Response
The versions of configuration and firmware do not
match.
—
The configuration does not start.
Possible cause
Test
Measure
Acknowledgement
Old firmware version
—
Apply a suitable configuration or
firmware.
—
Summary of Contents for POSIDYN SDS 5000