Parameterizing motor data
ID 442289.06
36
Operation manual POSIDYN® SDS 5000
5
WE
KEEP
THINGS
MOVING
5.2
Electronic type plate
STOBER servo motors are generally equipped with absolute value encoders. These encoders offer a special
parameter buffer. In the standard configuration, STOBER stores all motor data including the data of an
existing holding brake (if one is fitted) as an electronic nameplate in this memory. These data are automatically
read into the inverter each time the device starts up.
Manual changes to the motor data are only effective until the next device start-up, even if the changes have
been saved in the Paramodule in non-volatile memory.
Alternatively the commutation offset can only be used from the electronic nameplate. For this purpose chose
in parameter
B04
the setting
0:Commutation-offset
.
Information
A correct evaluation of the electronic nameplate is only guaranteed after a change of the
parameters
B06
and
B04
after a device restart.
Information
Electronic nameplates of other motor manufacturers cannot be evaluated.
Read all motor data from the electronic nameplate
1. Check whether you have an encoder with electronic nameplate.
2. In POSITool select the parameter list.
3. In
B20
, enter the control type
64:Servo control
.
4. In
B26
, parameterize the encoder interface X4 and activate the interface in
H00
with
64:EnDat
.
5. Set the parameter B06 to
0:electronic nameplate
.
6. In parameter B04, select the setting
1:All data
.
7. Go online and transfer the settings to the inverter.
8. Save the settings with
A00 Save values
.
The motor data and the control type are entered in the parameters.