![Stober POSIDYN SDS 5000 Operation Manual Download Page 153](http://html.mh-extra.com/html/stober/posidyn-sds-5000/posidyn-sds-5000_operation-manual_1381280153.webp)
Diagnosis
O
peration
man
ual
POSIDYN
®
SDS
5000
15
3
ID 442
289
.06
WE KEEP THINGS MOVING
13
18:X120-Timeout
No cycle signal was detected from
the SSI master.
•
Check the connected cable.
•
Check the power supply of the SSI master.
•
Make sure that the settings of all devices in the SSI
motion bus are matched to each other.
•
Check whether a device is correctly parameterized as
the SSL master in the SSI motion bus.
•
Check whether the devices in the SSI motion bus boot up
together.
Programmed
acknowledgement
19:X4 double
transmission
Different positions are frequently
determined at X4 during double
transmission.
•
Check the connection and shielding of the encoder
cable.
•
Reduce the electromagnetic interference.
Programmed
acknowledgement
20:X4-Busy
Encoder has not responded for too
long.
•
Check the encoder cable.
•
Check whether a suitable encoder is connected.
Programmed
acknowledgement
21:X4-wire break
A wire break from one or more
tracks was detected.
•
Check the encoder cable.
Programmed
acknowledgement
22:AX5000
Acknowledgement for axis
switchover did not occur.
Check the wiring between the inverter and POSISwitch
AX 5000.
Programmed
acknowledgement
23:AX5000required
A POSISwitch AX 5000 was
projected but not connected.
•
Match the projection of your hardware.
•
Check the connection of the POSISwitch AX 5000.
Programmed
acknowledgement
24:X120-speed
B297
,
G297
or
I297
exceeded for
the encoder at X120
•
Check the connection and shielding of the encoder
cable.
•
Reduce the electromagnetic interference.
•
Check the parameterization of
B297
,
G297
or
I297
.
Programmed
acknowledgement
25:X4-speed
B297
,
G297
or
I297
exceeded for
the encoder at X4
Programmed
acknowledgement
26:X4-noEnc.found
No encoder was found at X4 or a
wire break was detected at the
EnDat/SSI encoder.
•
Correct the connection of the encoder.
•
Check the encoder cable.
•
Correct the power supply of the encoder.
•
Check the setting of the
H00
parameter.
Programmed
acknowledgement
Cause
Description
Measure
Acknowledgeme
nt
Summary of Contents for POSIDYN SDS 5000