Parameterizing brake data
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
47
7
7
Parameterizing brake data
Motors with holding brakes can be connected to the devices oft the 5
th
generation of STOBER inverters. There
are two ways to activate the brake.
A brake control is integrated in the following applications:
•
Fast reference value with brake activation
•
Comfort reference value
•
Technology controller
•
Command positioning (endless and limited position range)
•
Synchronous command positioning (endless and limited position range)
•
Motion block positioning (endless and limited position range)
•
Electronic cam (endless and limited position range)
You can activate the brake control in parameter
F08
. Further adjustments are made depending on the
selected control mode.
In addition, a signal source can be parameterized in
F100
. The signal for releasing the brake can be given
direct via the source.
F100
is a global parameter and is available in every application.
If
F08
is set to
0:inactive
, the brake is activated together with system enable
A900
. In this case, the brake
release times and brake application times are ignored.
In the
F08 = 1:active
setting, the current motor torque is saved when the brake is applied. This torque is
applied again when the brake is released. If
F08
is set to
2:Do not save torque
, only the motor magnetization
is established when the brake is released.
As the brake controller parameterization depends on the selected control mode, the following sections are
subdivided accordingly.
Summary of Contents for POSIDYN SDS 5000
Page 194: ...Notes WE KEEP THINGS MOVING ...