Diagnosis
Operation
manual
POSIDYN®
SDS
5000
17
0
ID 44
22
8
9
.0
6
WE KEEP THINGS MOVING
13
11:SEA5001failure
SEA 5001 was detected, installed and
failed.
•
Uninstall the option, check the
contacts and reinstall the option.
•
Replace the option.
Switch the device on/off or
programmed acknowledgement
12:REA5001failure
REA 5001 was detected, installed and
failed.
•
Uninstall the option, check the
contacts and reinstall the option.
•
Replace the option.
Switch the device on/off or
programmed acknowledgement
13:PN5000 Failure1
PN 5000 was detected, installed and
failed. Basic hardware tests have
detected an error.
•
Check whether the PN 5000
accessory was correctly installed.
•
Check whether suitable EMC
measures were taken.
•
Check whether only PROFINET-
certified components were
connected to the inverter.
•
Check whether the cabeling and
connections correspond to the
PROFINET standard.
•
Contact the service department,
see section 1.4 Further support.
Switch device off/on
14:PN5000 failure2
PN 5000 was detected, installed and
failed. Basic software tests have
detected an error.
Switch device off/on
15:PN5000 failure3
PN 5000 was detected, installed and
failed. The watchdog function of the PN-
5000 monitoring system has detected
an error.
Switch device off/on
17:opt.2 too old
Option board with old hardware version
(XEA5001 HW 9, REA 5000 HW 18).
•
Install the latest version of the
option.
Switch device off/on
Cause
Description
Measure
Acknowledgement