Diagnosis
Operation
manual
POSIDYN®
SDS
5000
17
4
ID 44
22
8
9
.0
6
WE KEEP THINGS MOVING
13
13.3.23 60-67:Application events 0-7
13.3.24 68: External fault 2
Resolution
Level
Response
Fault counter
Application-specific or due to free
programming option; can be separately
programmed for each axis
•
Message/warning: Evaluation occurs in
256 ms cycle.
•
Malfunction: Evaluation occurs in
parameterized cycle time (
A150
)
Can be
parameterized
in the
U100
,
U110, U120
,
etc. up to
U170
system
parameters.
The parameterized malfunction reaction in the
A29
parameter.
Z60
to
Z67
Possible cause
Test
Measure
Acknowledgement
Application-specific or due to free programming
option; can be separately programmed for each axis
—
—
Switch the device on/off or
programmed acknowledgement
Triggering
Level
Response
Fault counter
Application-specific or by free programming
option; should be used for application events
that may only be parameterized on the fault
level.
Fault
The parameterized fault reaction in the
A29
parameter:
•
A29 = 0:inactive
The power unit is switched off, the motor coasts
down. The holding brakes are applied when the
purge override is inactive.
•
A29 = 1:active
The drive is stopped with a quick stop. The holding
brakes are applied at the end of a quick stop if the
purge override is inactive.
Z68
Possible cause
Test
Measure
Acknowledgement
Application-specific or by
free programming option
—
—
Switch the device off/on or
programmed acknowledgement