Integrated Bus
ID 442289.06
70
Operation manual POSIDYN® SDS 5000
11
WE
KEEP
THINGS
MOVING
Fig. 11-2: Direct connection to the PC and the components involved
You can also set up communication to a controller via the fieldbus in parallel to the IGB. Observe the fieldbus
documentation for this (see section 1.3 Further documentation).
11.1.1
Basics of IGB communication
Communication uses the following interfaces:
•
Direct connection: TCP/IP protocol on port 37915 and UDP/IP protocol on port 37915
•
Remote maintenance without proxy server: HTTP protocol on port 80
•
Remote maintenance with proxy server: HTTP protocol on port of the proxy server
You may be asked to share this port by the personal firewall. Share these port for your firewall. To do this,
contact your network administrator.
The IGB network must meet the following conditions:
•
A maximum of 32 SDS 5000s may be connected in one network.
•
All inverters involved in the IGB network must be directly connected with each other. No other components
such as hubs and switches are permitted between them in the circuit.
•
The overall resulting layout must be a line topology.
•
The X3 A interfaces may only be connected with X3 B interfaces of other inverters and vice versa.
•
Suitable cables must be used. STOBER provides ready-made cables for the layout of the Integrated Bus.
These cables must be used to ensure proper functionality. Note also the SDS 5000 projecting manual.
Information
Remember that when a fieldbus and the IGB-Motion bus are used at the same time, the fieldbus
communication cannot be synchronized on the controller.
Information
Remember that an IGB network can never be accessed by remote maintenance and direct
connection (PC) at the same time.