![Stober POSIDYN SDS 5000 Operation Manual Download Page 134](http://html.mh-extra.com/html/stober/posidyn-sds-5000/posidyn-sds-5000_operation-manual_1381280134.webp)
Service
ID 442289.06
134
Operation manual POSIDYN® SDS 5000
12
WE
KEEP
THINGS
MOVING
12.5
Actions
Actions are functions which are executed by the inverter automatically after their start.
Actions are controlled and analyzed using special parameters. The parameters contain three elements.
You can start the action via the element 0 (e.g.
A00.0
) The element 1 (e.g.
A00.1
) shows you the action's
progress. Element 2 (e.g.
A00.2
) shows the result. You can start an action via every interface (operator panel
on the inverter, fieldbus or POSITool in online mode).
For some actions, power must be applied to the motor and the motor must be free to turn. For this reason the
inverter must be enabled if you want to run these actions. Other actions can be performed without energizing
the motor. Since these two action groups are executed differently, they will be described separately below.
12.5.1
Actions without enable
Actions which do not need an enable before they can be executed are:
•
A00 Save values
•
A37 Reset memorized values
Proceed as shown below:
12.5.1.1
A00 Save values
When you activate
A00.0
, the inverter's current configuration and the parameter values are stored in
Paramodule, safe from loss due to a power failure. After power-off, the inverter starts with the configuration
stored in Paramodule.
When it is determined during the saving procedure that the configuration data in Paramodule and the inverter
are identical, only the parameters are stored. This speeds up the procedure.
You can read the following results from the third element (
A00.2
):
0: error free
10: write error
11: invalid data
12: write error
14: Warning
Executing actions without enable
1. Set element 0 of 0 to the value 1 (e.g.,
A00.0
= 1).
Element 1 indicates the progress of the action (e.g.,
A00.1
= 33 %).
2. Wait until element 0 indicates the value 0 again (e.g.,
A00.0
= 0)
Element 2 indicates the results of the action (e.g.,
A00.2 = 0:error free
).