Nynja Build manual 1.4d
movement and forms a control stop. A top hat bush should be fitted to
the bolt on the other side of the lever under its head.
Figure 314 spring fitting and control stop
f) Attach the inner cable to the lever
The cable wraps around the top hat bush and is secured using two
solderless nipples. The holes in these need to be drilled out to 3mm to
accommodate two lengths of the inner cable passing through.
Figure 315 cable connection and stop movement illustration
This bolt forms
control stop